  • Sensor Type:Semiconductor and electrochemical
  • Gas Sampling: Natural diffusion
  • Detect Range:Natural gas: 0~100%lel, CO: 0~100ppm
  • Presetting Alarm Level: Natural gas:7%lel, CO: 100ppm
  • Warm Up Time: 180±10S
  • Response Time: (t90)≤30S
  • Restore Time:≤30S
  • Working Voltage:AC90V~265V
  • Alarm Volume:≥70dB
  • Alarm Method:Visual and audible
  • Working Environment:Temperature: -10 ~ 50℃, Humidity: <95%RH (No dew)
  • Atmospheric Pressure:86kPa~106kPa
  • Storage Temperature:-25 ~ 55℃
  • Lifetime:3~5 Yeas
  • Weight:200g
  • Dimension:Φ120X26.5mm
  • Overview
Features:
Detect natural gas and carbon monoxide gas simultaneously;
Electrochemical CO sensor and flat surface semiconductor gas sensor with UL approval;
Anodized aluminum oxide and ABS engineering plastics combined shell;
Self-test and false alert function;
Plug in the socket directly, no need to install;
WIFI communication, App remote monitor.